Skip to Content Skip to main content Skip to content
Showroom hours

ADP registered vendor. Help with ODSP, March of Dimes, WSIB, VA and IFHP. ADP registered vendor. See if you qualify

Free in-home assessment across Toronto and the GTA. Free in-home assessment. Book a visit

Visit our showrooms in Etobicoke and Brampton. Showrooms in Etobicoke and Brampton. Find us

Service and repairs by our own team, at home or in store. Repairs by our own team. Request a repair

Joerns Healthcare

Joerns DermaFloat LAL replacement mattress, DFLAL-3680-M

The Joerns DermaFloat LAL mattress is the replacement surface for the LAL system: 36 or 42 in wide, 80 in long and 10 in high, with 20 cells, a 2 in safety cell and a 500 lb (227 kg) rating.

  • Sizes: 36 x 80 x 10 in (DFLAL-3680-M); 42 x 80 x 10 in (DFLAL-4280-M)
  • Construction: 20 horizontal 8 in cells in three zones over a 2 in safety cell
Product type
True low air loss replacement mattress
Edge
CairRails 2 in side air bolsters
Weight capacity
500 lbs227 kg
Warranty
2 years mattress; 1 year cover and electromechanical parts
Quote only

Priced by quote: your written quote confirms current pricing, options and availability.
  • Size

What is included?

The therapy mattress and its top pad in the width you choose. The DFLAL-CU control unit, hoses and bed frame are separate; confirm the carton before ordering.

  • Delivery and setup Across Toronto and the GTA: we set it up, show you how it works and service it at home or in our shop. Call (905) 798-1853
  • Safe checkout VISA Visa or Mastercard online, or pay in store when you visit us.
Brand
Joerns Healthcare
Barcode DFLAL-3680-M DFLAL-3680-M

Description

The Joerns DermaFloat LAL mattress is the replacement surface for the LAL low air loss system. It is 10 in high, comes in 36 or 42 in widths, and is rated 500 lbs (227 kg). The control unit is separate.

Who is it for?

  • An LAL control unit that still works, with a worn or torn mattress.
  • Joerns lists stage 1 to 4 pressure injuries, moisture management, rehabilitation, burns, neurology and amputations; the care team decides.
  • It is a full replacement, not an overlay, so the old mattress comes off.
  • With no pump yet, order the complete system or the control unit.

How the surface is built

  • Twenty horizontal 8 in cells sit in three zones, with a softer heel section.
  • The cells are polyurethane-coated nylon over a 1680 denier nylon base with bed loops.
  • A 2 in lower safety mattress stays inflated for up to 12 hours without power and supports transport.
  • CairRails are 2 in side air bolsters with a valve on the hose and a lower ingress area.
  • Three modes are available: Autofirm, Therapy and Pulsate, with eight comfort settings.
  • A CPR valve deflates the surface quickly.

Will it fit the bed?

  • 36 x 80 x 10 in (89 x 203 x 25 cm), code DFLAL-3680-M.
  • 42 x 80 x 10 in (106 x 203 x 25 cm), code DFLAL-4280-M. The wider build needs a wider frame.
  • Ten straps go to the moving part of the bed frame, plus six pad straps. The hose connects at the foot.
  • 500 lbs (227 kg) is the mattress limit; the bed frame's own limit applies if it is lower.
  • At 10 in it sits higher than a foam mattress; check the gaps beside the rails: Health Canada recommends under 120 mm (4 3/4 in) within and under the rail, and under 60 mm (2 3/8 in) at the rail ends.
  • A used mattress cannot be returned. Measure first and read the return policy.

Cover and care

  • The two-way stretch nylon therapy pad is low friction, fluid proof, moisture vapour permeable and treated with a bacteriostat.
  • Wipe it, or launder it at no more than 120 F (49 C) with a non-bleach detergent. Do not steam the mattress.

How does it compare?

Frequently asked questions

Will my old DermaFloat LAL pump run this mattress?

Yes, if it is the LAL control unit, DFLAL-CU. An APL pump is a different system.

Is it an overlay?

No. It is a full 10 in replacement mattress; the old mattress comes off the deck.

Which width should I pick?

Match the deck. 36 in is the usual home-care width; 42 in needs a wider bed and frame.

What stays up during a power cut?

The 2 in safety mattress holds for up to 12 hours. The therapy cells need the pump, so the care team's outage plan still applies.

Funding may help: see who may help pay.

We put it on the bed and strap it down. Warranty: two years on the mattress, one year on the cover and electromechanical parts; see the Warranty tab.

Specifications

Weight capacity
500 lbs (227 kg); the bed frame limit also applies
Product weight
22 lbs (10 kg), mattress only
Construction
20 horizontal 8 in cells in three zones, with a softer heel section
Cover
Two-way stretch nylon therapy pad, low friction, fluid proof, moisture vapour permeable, bacteriostat treated
Cover care
Wipe, or launder at no more than 120 F (49 C) with a non-bleach detergent; no steam
Therapy modes
Autofirm, Therapy and Pulsate
Comfort settings
Eight settings
CPR release
CPR quick deflation
Edge support
CairRails 2 in side air bolsters with a valve on the hose
Power failure protection
2" safety cell stays inflated up to 12 hours
Mattress width
36 in (89 cm) or 42 in (106 cm)
Mattress length
80 in (203 cm)
Mattress height
10 in (25 cm): 8 in cells on a 2 in safety cell
Base
1680 denier nylon with a 1.5 oz urethane coating and bed loops
Straps
Ten bed straps, plus six pad straps
Control unit
DFLAL-CU, sold separately; complete system code DFLAL3680NZ
Cell material
Polyurethane-coated nylon
Safety cell
2 in lower safety mattress, stays inflated up to 12 hours without power
Warranty
Mattress 2 years; cover 1 year; electromechanical parts 1 year
Product type
True low air loss replacement mattress

Figures from the manufacturer. Options and seat sizes can change them; we confirm yours before ordering.

Documents

Delivery and service

Delivery and setup

We deliver and set up equipment across Toronto and the GTA, and show you how everything works. Custom and special-order products can take longer; we confirm timing with you before delivery.

Service and repairs

Our technicians service what we sell, at home or in our shop.

Try before you buy

Visit a showroom in Etobicoke or Brampton to try products first, or book a free home assessment.

Warranty

Warranty details

Joerns Healthcare warrants the DermaFloat LAL support surface (mattress and control unit) against defects in workmanship and materials under normal and proper use. The warranty covers the original purchaser.

  • Mattress: 2 years.
  • Cover and electromechanical parts (compressors, valves, circuit boards, hoses and couplers): 1 year.
  • Joerns supplies replacement parts, or services or replaces a defective product, at its option.
  • Excludes burns, improper chemicals, needle punctures, cuts or abrasions, excessive loads, staining, improper maintenance or cleaning, use against the manual, and unauthorized modification or repair.

Questions about this product?

Talk to our team, try it in a showroom, or book a free home assessment. We help with sizing and funding.

Not sure where to start?

Talk to a specialist. No pressure, no obligation.

Book a free visit